==NILAI PRETEST Pre-postest kardiovascular 2

235 Electrocardiography Ary L. Goldberger Sinoatrial (SA) node AV junction AV node His bundle RA RV Right bundle branch LV Ventricular myocardium Purkinje fibers Left bundle branch Ventricular septum FIGURE 235-1 Schematic of the cardiac conduction system. triggering coordinated ventricular contraction. Since the cardiac depo larization and repolarization waves have directions and magnitudes, they can be represented by vectors. ■ECG WAVEFORMS AND INTERVALS The ECG waveforms are labeled alphabetically, beginning with the P wave, which represents atrial depolarization (Fig. 235-2). The QRS complex represents ventricular depolarization, and the ST-T-U complex (ST segment, T wave, and U wave) represents ventricular repolarization. The J point is the junction between the end of the QRS complex and the beginning of the ST segment. Atrial repolarization waveforms (ST-Ta ) are usually of too low in amplitude to be detected, it may become apparent in acute pericarditis, atrial infarction, and AV An electrocardiogram (ECG or EKG) is a graphic representation of elec trical activity generated by the heart. The signals, detected by means of metal electrodes attached to the extremities and chest wall, are ampli fied and recorded by the electrocardiograph. ECG leads (derivations) are configured to display the instantaneous differences in potential between specific pairs of electrodes. The utility of the ECG derives from its immediate availability as a noninvasive, inexpensive, and highly versa tile test. In addition to its use in detecting arrhythmias and myocardial ischemia, it may reveal findings related to life-threatening metabolic disturbances or to increased susceptibility to sudden cardiac arrest (see also Chaps. 299 and 401). ■ELECTROPHYSIOLOGIC BACKGROUND Depolarization of the heart is the initiating event for cardiac contrac tion. The electric currents that spread through the heart are produced by three components: cardiac pacemaker cells, specialized conduction tissue, and the heart muscle itself. The ECG records only the depolar ization (stimulation) and repolarization (recovery) potentials gener ated by the “working” atrial and ventricular myocardium (see also Chaps. 239 and 241). The stimulus initiating the normal heartbeat originates in the sinoatrial (SA) node (Fig. 235-1), which possesses spontaneous automa ticity. Spread of the depolarization wave through the right and left atria induces contraction of these chambers. Next, the impulse stimulates specialized conduction tissues in the atrioventricular (AV) nodal and His-bundle areas; together, these two regions constitute the AV junction. The bundle of His fans bifurcates into two main branches, the right and left bundles, which rapidly transmit depolarization wavefronts in a synchronous way to the right and left ventricular myocardium by way of Purkinje fibers. The main left bundle bifurcates into left anterior and left posterior fascicle subdivisions. The depolarization wavefronts then spread through the ventricular wall, from endocardium to epicardium, heart block. The QRS-T waveforms of the surface ECG correspond in a general way with the different phases of simultaneously obtained ventricular action potentials, the intracellular recordings from single myocardial fibers (Chap. 239). The rapid upstroke (phase 0) of the action potential corresponds to the onset of QRS. The plateau (phase 2) corresponds to the isoelectric ST segment, and active repolarization (phase 3) cor responds to the inscription of the T wave. Factors that decrease the slope of phase 0 by impairing the influx of Na+ (e.g., hyperkalemia and drugs such as flecainide) tend to increase QRS duration. Conditions that prolong phase 2 or 3 (amiodarone, hypocalcemia) increase the QT interval. In contrast, factors (e.g., hypercalcemia, digoxin) associated with shortening of ventricular repolarization duration shorten the QT. QRS P PR interval ST J T QRS interval QT interval U FIGURE 235-2 Basic ECG waveforms and intervals. Not shown is the RR interval, the time between consecutive QRS complexes. CHAPTER 235 Electrocardiography PART 6 Disorders of the Cardiovascular System 1676 The ECG is usually recorded on graph paper divided into 1-mm2 gridlike boxes. When the recording speed of 25 mm/s, the smallest (1 mm) horizontal divisions correspond to 0.04 (40 ms), with heavier lines at intervals of 0.20 s (200 ms). Vertically, the ECG graph measures the amplitude of a specific wave or deflection (1 mV = 10 mm with stan dard calibration; the voltage criteria for hypertrophy mentioned below are given in millimeters). There are four major sets of ECG intervals: RR, PR, QRS, and QT/QTc (Fig. 235-2). The instantaneous heart rate (beats per minute) can be computed from the interbeat (RR) interval by dividing the number of large (0.20 s) time units between consecutive R waves into 300 or the number of small (0.04 s) units into 1500. The PR interval measures the time (normally 120–200 ms) between atrial and ventricular depolarization, which includes the physiologic delay imposed by stimulation of cells in the AV junction area. The QRS inter val (normally 100–110 ms or less) reflects the duration of ventricular depolarization. The QT interval subtends both ventricular depolariza tion and (primarily) repolarization times and varies inversely with the heart rate. A rate-related (“corrected”) QT interval, QTc , can be calcu lated as QT/6RR and is normally 70.44 s. Some references give the QTc upper normal limits as 0.45 s in men and 0.46 s in women. A number of other rate-correction formulas have been proposed, without consensus. ■ECG LEADS The 12 conventional ECG leads are divided into two groups: six limb (extremity) leads and six chest (precordial) leads. The limb leads record potentials transmitted onto the frontal plane (Fig. 235-3A); the chest leads record potentials transmitted onto the horizontal plane (Fig. 235-3B). The orientation and polarity of the frontal plane leads are represented on a hexaxial diagram (Fig. 235-4). The six chest leads are obtained by exploring electrodes as shown in Fig. 235-5. Each lead is analogous to a different video camera angle “looking” at the same events—atrial and ventricular depolarization and repolarization—from different spatial orientations. The 12-lead ECG can be supplemented with additional leads in special circumstances. For example, right precordial leads V3 R to V6 R are useful in detecting evidence of acute right ventricular ischemia. Bedside monitors and ambulatory ECG (Holter and event) recordings usually employ only one or two modified leads. The ECG leads are configured such that a positive (upright) deflection is recorded in a lead if a wave of depolar ization spreads toward the positive pole of that lead, and a negative deflection is recorded if the wave spreads toward the negative pole. If the mean orientation of the depolarization vector is at right angles to a particular lead axis, a biphasic (equally positive and negative) deflec tion will be recorded. GENESIS OF THE NORMAL ECG ■P WAVE The normal atrial depolarization vector is oriented downward and toward the subject’s left, reflecting the spread of depolarization from the sinus node to the right and then the left atrial myocardium. Since this vector points toward the positive pole of lead II and toward the A Superior Inferior Right Left +–––––– + + + + + aVR aVL II III aVF B Posterior Right Left + + + + + + V6 V5 V4 V3 V2 V1 Anterior––––– I FIGURE 235-3 The six frontal plane (A) and six horizontal plane (B) leads provide a three dimensional representation of cardiac electrical activity. Right axis deviation Normal axis Left axis deviation–90°–aVF–60°–III–30° +aVL 0° +I +30°–aVR +60° +II +90° +aVF +120° +III +150°–aVL 180°–I–150° +aVR–120°–II Extreme axis deviation FIGURE 235-4 The frontal plane (limb or extremity) leads are represented on a hexaxial diagram. Each ECG lead has a speci c spatial orientation and polarity. The positive pole of each lead axis (solid line) and the negative pole (hatched line) are designated by their angular position relative to the positive pole of lead I (0°). The mean electrical axis of the QRS complex is measured with respect to this display. negative pole of lead aVR, the normal P wave will be positive in lead II and negative in aVR. By contrast, activation of the atria from an ecto pic pacemaker in the lower part of either atrium or in the AV junction region may produce retrograde P waves (negative in II, positive in aVR). The normal P wave in lead V1 may be biphasic with a positive component reflecting right atrial depolarization, followed by a small (<1 mm2) negative component reflecting left atrial depolarization. ■QRS COMPLEX Normal ventricular depolarization proceeds as a rapid, continu ous spread of activation wave fronts. This complex process can be divided into two major sequential phases, and each phase can be represented by a mean vector (Fig. 235-6). The first phase is depo larization of the interventricular septum from the left to the right and anteriorly (vector 1). The second results from the simultaneous depolarization of the right and left ventricles; it normally is dom inated by the more massive left ventricle, so that vector 2 points leftward and posteriorly. Therefore, a right precordial lead (V1 ) will record this biphasic depolarization process with a small positive deflection (septal r wave) followed by a larger negative deflection (S wave). A left precordial lead, for example, V6 , will record the same sequence with a small negative deflection (septal q wave) followed by a relatively tall positive deflec tion (R wave). Intermediate leads show a relative increase in R-wave amplitude (normal R-wave pro gression) and a decrease in S-wave amplitude pro gressing across the chest from right to left. The lead where the R and S waves are of about equal amplitude is referred to as the transition zone (usually V3 or V4 ) (Fig. 235-7). The QRS pattern in the extremity leads may vary con siderably from one normal subject to another depending on the electrical axis of the QRS, which describes the mean orientation of the QRS vector with reference to the six frontal plane leads. Normally, the QRS axis ranges from 830° to +100° (Fig. 235-4). An axis more negative than –30° is referred to as left axis deviation, and an axis more positive than +90 to +100° is referred to as right axis devia tion. Left axis deviation may occur as a normal variant but 1677 V1 V3R V4R V2 V3 V4 V5 V6 FIGURE 235-5 The horizontal plane (chest or precordial) leads are obtained with electrodes in the locations shown. Additional posterior leads are sometimes placed on the same horizontal plane as V4 to facilitate detection of acute posterolateral infarction (V7 , midaxillary line; V8 , posterior axillary line; and V9 , posterior scapular line). Right chest leads (V3 R–V6 R) may enhance detection of right ventricular involvement in the context of inferior infarction. r V1 A RV LV 1 V1 r V1 B RV q V6 LV S 2––––– 2 1 + + + C + V1 V2 V3 V4 R q + V6 + V5 V6 FIGURE 235-6 Ventricular depolarization can be divided into two major phases, each represented by a vector. A. The rst phase (arrow 1) denotes depolarization of the ventricular septum, beginning on the left side and spreading to the right. This process is represented by a small “septal” r wave in lead V1 and a small septal q wave in lead V6 . B. Simultaneous depolarization of the left and right ventricles (LV and RV) constitutes the second phase. Vector 2 is oriented to the left and posteriorly, reecting the electrical predominance of the LV. C. Vectors (arrows) representing these two phases are shown in reference to the horizontal plane leads. (After AL Goldberger et al: Goldberger’s Clinical Electrocardiography: A Simplified Approach, 9h ed. Philadelphia, Elsevier/Saunders, 2017.) is more commonly associated with left ventricular hypertrophy, a block in the anterior fascicle of the left bundle system (left anterior fascicu lar block or hemiblock), or inferior myocardial infarction. Right axis deviation also may occur as a normal variant (particularly in children and young adults), as a spurious finding due to reversal of the left and right arm electrodes, or in conditions such as right ventricular overload (acute or chronic), lateral infarction, dextrocardia, left pneumothorax, and left posterior fascicular block. ■T WAVE AND U WAVE Normally, the mean T-wave vector is oriented roughly concordant with the mean QRS vector (within about 45° in the frontal plane). Since depo larization and repolarization are electrically opposite processes, this normal QRS–T-wave vector concordance indicates that repolarization normally must proceed in the reverse direction from depolarization (i.e., from ventricular epicardium to endocardium). The normal U wave is a small, rounded deflection (71 mm) that follows the T wave and usually has the same polarity as the T wave. An abnormal increase in U-wave amplitude is most commonly due to drugs (e.g., dofetilide, amiodarone, sotalol, quinidine) or to hypokalemia. Very prominent U waves are a marker of increased susceptibility to torsades de pointes (Chap. 241). CHAPTER 235 Electrocardiography MAJOR ECG ABNORMALITIES ■CARDIAC ENLARGEMENT AND HYPERTROPHY Right atrial overload (acute or chronic) may lead to an increase in P-wave amplitude (32.5 mm) (Fig. 235-8), previously referred to as “P-pulmonale.” Left atrial overload typically produces a biphasic P wave in V1 with a broad negative component or a broad (3120 ms), often notched P wave in one or more limb leads (Fig. 235-8). This pattern, previously referred to as “P-mitrale,” may also occur with left atrial conduction delays in the absence of actual atrial enlargement, leading to the more general designation of left atrial abnormality. Right ventricular hypertrophy due to a sustained, severe pressure load (e.g., due to tight pulmonic valve stenosis or certain pulmonary artery hypertension syndromes) is characterized by a relatively tall R wave in lead V1 (R 3 S wave), usually with right axis deviation (Fig. 235-9); alternatively, there may be a qR pattern in V1 or V3 R. ST depression and T-wave inversion in the right-to-midprecordial leads are also often present. This pattern, formerly called right ventricular “strain,” is attributed to repolarization abnormalities in acutely or chronically overloaded muscle. Prominent S waves may occur in the left lateral precordial leads. Right ventricular hypertrophy due to ostium secundum–type atrial septal defects, with the accompanying right ventricular volume overload, is commonly associated with an incomplete or complete right bundle branch block pattern with a right ward QRS axis. Acute cor pulmonale due to pulmonary embolism (Chap. 273), for example, may be associated with a normal ECG or a variety of abnor malities. Sinus tachycardia is the most common arrhythmia, although other tachyarrhythmias, such as atrial fibrillation or flutter, may occur. The QRS axis may shift to the right, sometimes in concert with the so-called S1 Q3 T3 pattern (prominence of the S wave in lead I and the Q wave in lead III, with T-wave inversion in lead III). Acute right ven tricular dilation also may be associated with slow R-wave progression and ST-T abnormalities in V1 to V4 simulating acute anterior infarction. A right ventricular conduction disturbance may appear. Chronic cor pulmonale due to obstructive lung disease (Chap. 252) usually does not produce the classic ECG patterns of right ventricular hypertrophy noted above. Instead of tall right precordial R waves, chronic lung disease more typically is associated with small R waves in right-to-midprecordial leads (slow R-wave progression) due in part to downward displacement of the diaphragm and the heart. Low-voltage complexes are commonly present, owing to hyperaeration. Multiple voltage criteria for left ventricular hypertrophy (Fig. 235-9) have been proposed on the basis of the presence of tall left precordial R waves and deep right precordial S waves (e.g., SV1 + [RV5 or RV6 ] >35 mm). Repolarization abnormalities (ST depression with T-wave inversions, formerly called the left ventricular “strain” pattern) also 1678 I PART 6 Disorders of the Cardiovascular System II III aVR aVL aVF V1 V2 V3 V4 V5 V6 FIGURE 235-7 Normal electrocardiogram from a healthy subject. Sinus rhythm is present with a heart rate of 75 beats per minute. PR interval is 0.16 s; QRS interval (duration) is 0.08 s; QT interval is 0.36 s; QTc is 0.40 s; the mean QRS axis is about +70°. The precordial leads show normal R-wave progression with the transition zone (R wave = S wave) in lead V3 . may appear in leads with prominent R waves. However, prominent precordial voltages may occur as a normal variant, especially in ath letic or young individuals. Left ventricular hypertrophy may increase limb lead voltage with or without increased precordial voltage (e.g., RaVL + SV3 >20 mm in women and >28 mm in men). The presence of left atrial abnormality increases the likelihood of underlying left ventricular hypertrophy in cases with borderline voltage criteria. Left ventricular hypertrophy often progresses to incomplete or complete left bundle branch block. The sensitivity of conventional voltage cri teria for left ventricular hypertrophy is decreased in obese persons and smokers. ECG evidence for left ventricular hypertrophy is a major noninvasive marker of increased risk of cardiovascular morbidity and mortality rates, including sudden cardiac death. However, because of false-positive and false-negative diagnoses, the ECG is of limited utility in diagnosing atrial or ventricular enlargement. More definitive information is provided by echocardiography (Chap. 236). RA LA V1 Normal RA II LA V1 RA RA Right RA LA Left RA RA LA LA LA LA ■BUNDLE BRANCH BLOCKS AND RELATED PATTERNS Intrinsic impairment of conduction in either the right or the left bundle system (intraventricular conduction disturbances) leads to prolon gation of the QRS interval. With complete bundle branch blocks, the widest QRS interval is 3120 ms in duration; with incomplete blocks, the QRS interval is between about 110 and 120 ms. The QRS vector usually is oriented in the direction of the myocardial region where depolarization is delayed (Fig. 235-10). Thus, with right bundle branch block, the terminal QRS vector is oriented to the right and anteriorly (rSR′ in V1 and qRS in V6 , typically). Left bundle branch block alters both early and later phases of ventricular depolarization. The major QRS vector is directed to the left and posteriorly. In addition, the nor mal early left-to-right pattern of septal activation is disrupted such that QRS in hypertrophy V1 Normal LVH or RVH or Main QRS vector V6 V1 V6 FIGURE 235-8 Right atrial (RA) overload may cause tall, peaked P waves in the limb or precordial leads. Left atrial (LA) abnormality may cause broad, often notched P waves in the limb leads and a biphasic P wave in lead V1 with a prominent negative component representing delayed depolarization of the LA. (After MK Park, WG Guntheroth: How to Read Pediatric ECGs, 4th ed. St. Louis, Mosby/Elsevier, 2006.) FIGURE 235-9 Left ventricular hypertrophy (LVH) increases the amplitude of electrical forces directed to the left and posteriorly. In addition, repolarization abnormalities may cause ST-segment depression and T-wave inversion in leads with a prominent R wave. Right ventricular hypertrophy (RVH) may shift the QRS vector to the right; this effect usually is associated with an R, RS, or qR complex in lead V1 . T-wave inversions may be present in right precordial leads. 1679 CHAPTER 235 Electrocardiography QRS changes and are related instead to actual alterations in the electri cal properties of the myocardial fibers themselves (e.g., in the resting membrane potential or action potential duration), not just to changes in the sequence of repolarization. Ischemia, electrolyte imbalance, and drugs such as digitalis all cause such primary ST–T-wave changes. Primary and secondary T-wave changes may coexist. For example, T-wave inversions in the right precordial leads with left bundle branch block or in the left precordial leads with right bundle branch block may be important markers of underlying ischemia or other abnormalities. A distinctive abnormality simulating right bundle branch block with ST-segment elevations in the right chest leads is seen with the Brugada pattern (Chap. 250). Partial blocks (fascicular or “hemiblocks”) in the left bundle system (left anterior or posterior fascicular blocks) generally do not prolong the QRS duration substantially but instead are associated with shifts in the frontal plane QRS axis (leftward or rightward, respectively). Left anterior fascicular block (QRS axis more negative than –45°) is prob ably the most common cause of marked left axis deviation in adults. In contrast, left posterior fascicular block (QRS axis more rightward than +110–120°) is extremely rare as an isolated finding and requires exclusion of other factors causing right axis deviation mentioned ear lier. Intraventricular conduction delays also can be caused by extrinsic (toxic) factors that slow ventricular conduction, particularly hyper kalemia or drugs (e.g., class 1 antiarrhythmic agents, tricyclic antide pressants, phenothiazines). Prolongation of QRS duration does not necessarily indicate a conduction delay but may be due to preexcitation of the ventricles via a bypass tract, as in Wolff-Parkinson-White (WPW) patterns (Chap. 244) and related variants. V6 V1 S R q T R′ Normal r RBBB S ■MYOCARDIAL ISCHEMIA AND INFARCTION (See also Chap 269) The ECG is central to the diagnosis of acute and chronic ischemic heart disease. Ischemia exerts complex time-dependent effects on the electrical properties of myocardial cells. Severe, acute ischemia lowers the resting membrane potential and shortens the duration of the action potential. Such changes cause a voltage gradient between normal and ischemic zones. As a consequence, current flows between those regions. These currents of injury are represented on the surface ECG by deviation of the ST segment (Fig. 235-11). When the acute ischemia is transmural, the ST vector usually is shifted in the direction of the outer (epicardial) layers, producing ST elevations and sometimes, in the earliest stages of ischemia, tall, positive so-called hyperacute T waves over the ischemic zone. With ischemia confined primarily to the subendocardium, the ST vector typically shifts toward the subendocar dium and ventricular cavity, so that overlying (e.g., anterior precordial) leads show ST-segment depression (with ST elevation in lead aVR). Multiple factors affect the amplitude of acute ischemic ST deviations. Profound ST elevation or depression in multiple leads usually indicates very severe ischemia. From a clinical viewpoint, the division of acute myocardial infarction into ST-segment elevation and non-ST elevation types is useful since the consistent efficacy of emergency (minutes to hours) reperfusion therapy is limited to the former group; the evolving indications for acute reperfusion therapy in non-ST elevation MI are a focus of intensive investigation (see Chap. 268). Takostubo syndrome may exactly simulate the patterns of STEMI or non-STEMI (Chap. 266). T LBBB FIGURE 235-10 Comparison of typical QRS-T patterns in right bundle branch block (RBBB) and left bundle branch block (LBBB) with the normal pattern in leads V1 and V6 . Note the secondary T-wave inversions (arrows) in leads with an rSR′ complex with RBBB and in leads with a wide R wave with LBBB. septal depolarization proceeds from right to left as well. As a result, left bundle branch block generates wide, predominantly negative (QS) complexes in lead V1 and entirely positive (R) complexes in V6 . A pat tern identical to that of left bundle branch block, preceded by a sharp spike, is seen in most cases of electronic right ventricular pacing due to the relative delay in left ventricular activation. Bundle branch block may occur in a variety of conditions. In subjects without structural heart disease, right bundle branch block is seen more commonly than left bundle branch block. Right bundle branch block also occurs with heart disease, both congenital (e.g., atrial septal defect) and acquired (e.g., valvular, ischemic). Left bundle branch block is often a marker of one of four underlying conditions associated with increased risk of cardiovascular morbidity and mortality rates: coro nary heart disease (frequently with impaired left ventricular function), hypertensive heart disease, aortic valve disease, and cardiomyopathy. Bundle branch blocks may be chronic or intermittent. A bundle branch block may be rate-related; for example, it often occurs when the heart rate exceeds some critical value. Bundle branch blocks and depolarization abnormalities secondary to artificial pacemakers not only affect ventricular depolarization (QRS) but also are characteristically associated with secondary repolarization (ST-T) abnormalities. With bundle branch blocks, the T wave is typi cally opposite in polarity to the last deflection of the QRS (Fig. 235-10). This discordance of the QRS–T-wave vectors is caused by the altered sequence of repolarization that occurs secondary to altered depolariza tion. In contrast, primary repolarization abnormalities are independent of V5 ST ST B V5 ST A ST FIGURE 235-11 Acute ischemia causes a current of injury. With predominant subendocardial ischemia (A), the resultant ST vector will be directed toward the inner layer of the affected ventricle and the ventricular cavity. Overlying leads therefore will record ST depression. With ischemia involving the outer ventricular layer (B) (transmural or epicardial injury), the ST vector will be directed outward. Overlying leads will record ST elevation. 1680 V1 V2 V3 V4 V5 V6 PART 6 Disorders of the Cardiovascular System FIGURE 235-12 Severe anterior wall ischemia (with or without infarction) may cause prominent T-wave inversions in the precordial leads and in leads I and aVL. This pattern (sometimes referred to as Wellens T waves) is usually associated with a high-grade stenosis of the left anterior descending coronary artery. The ECG leads are usually more helpful in localizing regions of ST elevation than non-ST elevation ischemia. For example, acute trans mural anterior (including apical and lateral) wall ischemia is reflected by ST elevations or increased T-wave positivity in one or more of the precordial leads (V1–V6 ) and leads I and aVL. Inferior wall ischemia produces changes in leads II, III, and aVF. “Posterior” wall ischemia (usually associated with lateral or inferior involvement) may be indi rectly recognized by reciprocal ST depressions in leads V1 to V3 (thus constituting an ST elevation “equivalent” acute coronary syndrome). Right ventricular ischemia usually produces ST elevations in right sided chest leads (Fig. 235-5). When ischemic ST elevations occur as the earliest sign of acute infarction, they typically are followed within a period ranging from hours to days by evolving T-wave inversions and often by Q waves occurring in the same lead distribution. Revers ible transmural ischemia, for example, due to coronary vasospasm (Prinzmetal’s angina) may cause transient ST-segment elevations with out development of Q waves. Depending on the severity and duration of ischemia, the ST elevations may resolve completely in minutes or be followed by T-wave inversions that persist for hours or even days. Patients with ischemic chest pain who present with deep T-wave inversions in multiple precordial leads (e.g., V1–V4 , I, and aVL) with or without cardiac enzyme elevations typically have severe obstruction in the left anterior descending coronary artery (Fig. 235-12). With infarction, depolarization (QRS) changes often accompany repolarization (ST-T) abnormalities. Necrosis of sufficient myocar dial tissue may lead to decreased R-wave amplitude or abnormal Q waves (even in the absence of transmural ischemia) in the anterior or inferior leads (Fig. 235-13). Abnormal Q waves were once considered markers of transmural myocardial infarction, whereas subendocardial A Evolving B Early Evolving ECG sequence with anterior Q-wave infarction I II III Early aVR ECG sequence with inferior Q-wave infarction I II III aVR infarcts were thought not to produce Q waves. However, careful ECG pathology correlative studies have indicated that transmural infarcts may occur without Q waves and that subendocardial (nontransmural) infarcts sometimes may be associated with Q waves. Therefore, evolv ing or chronic infarcts are more appropriately classified as “Q-wave” or “non-Q-wave” (Chap. A7). Loss of depolarization forces due to posterior or lateral infarction may cause reciprocal increases in R-wave amplitude in leads V1 and V2 without diagnostic Q waves in any of the conventional leads. (Additional leads V7-V9 may show acute changes.) In the weeks and months after infarction, these ECG changes may persist or begin to resolve. Complete normalization of the ECG after Q-wave infarction is uncommon but may occur, particularly with smaller infarcts. In contrast, ST-segment elevations that persist for several weeks or more after a Q-wave infarct usually correlate with a severe underlying wall motion disorder, although not necessarily a frank ventricular aneurysm. The ECG has important limitations in both sensitivity and specificity in the diagnosis of ischemic heart disease. Although a single normal ECG does not exclude ischemia or even acute infarction, a normal ECG throughout the course of an acute infarct is distinctly uncommon. Prolonged chest pain without diagnostic ECG changes therefore should always prompt a careful search for other noncoronary causes of chest pain (Chap. 11). Furthermore, the diagnostic changes of acute or evolving ischemia are often masked by the presence of left bundle branch block, electronic ventricular pacemaker patterns, and Wolff- Parkinson-White preexcitation. However, clinicians continue to over- diagnose ischemia or infarction based on the presence of ST-segment elevations or depressions; T-wave inversions; tall, positive T waves; or Q waves not related to ischemic heart disease (pseudoinfarct patterns). aVL aVF V2 V4 V6 aVL aVF V2 V4 V6 FIGURE 235-13 Sequence of depolarization and repolarization changes with (A) acute anterior and (B) acute inferior wall Q-wave infarctions. With anterior infarcts, ST elevation in leads I and aVL and the precordial leads may be accompanied by reciprocal ST depressions in leads II, III, and aVF. Conversely, acute inferior (or posterolateral) infarcts may be associated with reciprocal ST depressions in leads V1 to V3 . (After AL Goldberger et al: Goldberger’s Clinical Electrocardiography: A Simplified Approach, 9th ed. Philadelphia, Elsevier/Saunders, 2017.) 1681 TABLE 235-1 Differential Diagnosis of ST-Segment Elevations Ischemia/myocardial infarction Noninfarction, transmural ischemia (Prinzmetal’s angina, and probably Tako tsubo syndrome, which may also exactly simulate classical acute infarction) Acute myocardial infarction Postmyocardial infarction (ventricular aneurysm pattern) Acute pericarditis Normal variants (including benign “early repolarization” patterns) Left ventricular hypertrophy/left bundle branch blocka Other (rarer) Acute pulmonary embolisma Brugada patterns (right bundle branch block–like pattern with ST elevations in right precordial leads)a Class 1C antiarrhythmic drugsa DC cardioversion Hypercalcemiaa Hyperkalemiaa Hypothermia (J [Osborn] waves) Nonischemic myocardial injury Myocarditis Tumor invading left ventricle Trauma to ventricles aUsually localized to V1–V2 or V3 . Source: Modified from AL Goldberger et al: Goldberger’s Clinical Electrocardiography: A Simplified Approach, 9th ed. Philadelphia, Elsevier/ Saunders, 2017. For example, ST-segment elevations simulating ischemia may occur with acute pericarditis or myocarditis, as a normal variant (including the typical “early repolarization” pattern), or in a variety of other conditions (Table 235-1). Similarly, tall T waves do not invariably rep resent hyperacute ischemic changes but may also be caused by normal variants, hyperkalemia, cerebrovascular injury, among other causes. ST-segment elevations and tall, positive T waves are common find ings in leads V1 and V2 in left bundle branch block or left ventricular hypertrophy in the absence of ischemia. The differential diagnosis of Q waves includes physiologic or positional variants, ventricular hyper trophy, acute or chronic noncoronary myocardial injury, hypertrophic cardiomyopathy, and ventricular conduction disorders. Digoxin, ven tricular hypertrophy, hypokalemia, and a variety of other factors may cause ST-segment depression mimicking subendocardial ischemia. Prominent T-wave inversion may occur with ventricular hypertrophy, cardiomyopathies, myocarditis, and cerebrovascular injury (particu larly intracranial bleeds), among others causes. ■METABOLIC FACTORS AND DRUG EFFECTS A variety of metabolic abnormalities and pharmacologic agents alter the ECG and, in particular, causing changes in repolarization (ST-T-U) and sometimes QRS prolongation. Certain life-threatening electrolyte disturbances may be diagnosed initially and monitored from the ECG. Hyperkalemia produces a sequence of changes (Fig. 235-14), usually beginning with narrowing and peaking (tenting) of the T waves. Further elevation of extracellular K+ leads to AV conduction distur bances, diminution in P-wave amplitude, and widening of the QRS interval. Severe hyperkalemia eventually causes cardiac arrest with a slow sinusoidal type of mechanism (“sine-wave” pattern) followed by asystole. Hypokalemia (Fig. 235-15) prolongs ventricular repolariza tion, often with prominent U waves. Prolongation of the QT interval is also seen with drugs that increase the duration of the ventricular action potential: class 1A antiarrhythmic agents and related drugs (e.g., quinidine, disopyramide, procainamide, tricyclic antidepressants, phenothiazines) and class III agents (e.g., amiodarone [Fig. 235-15], dofetilide, sotalol, ibutilide). Systemic hypothermia (Fig. 235-15) also prolongs repolarization, usually with a distinctive convex elevation of the J point (Osborn wave). Marked QT prolongation, sometimes with deep, wide T-wave inversions, may occur with intracranial bleeds, particularly subarachnoid hemorrhage (“CVA T-wave” pattern) (Fig. 235-15). Hypocalcemia typically prolongs the QT interval (ST portion), whereas hypercalcemia shortens it (Fig. 235-16). Digitalis gly cosides also shorten the QT interval, often with a characteristic “scoop ing” of the ST–T-wave complex (digitalis effect). ■NON-SPECIFIC ST-T CHANGES AND LOW QRS VOLTAGE Many other factors are associated with ECG changes, particularly alterations in ventricular repolarization. T-wave flattening, minimal T-wave inversions, or slight ST-segment depression (“nonspecific ST–T-wave changes”) may occur with a variety of electrolyte and acid-base disturbances, infectious or inflammatory processes, central nervous system disorders, endocrine abnormalities, many drugs, ische mia, hypoxia, and virtually any type of cardiopulmonary abnormality, in addition to physiologic changes (e.g., with posture or with meals). Low QRS voltage is arbitrarily defined as peak-to-trough QRS ampli tudes of 75 mm in the six limb leads and/or 710 mm in the chest leads. Multiple factors may be responsible. Among the most serious include pericardial (Fig. 235-17) or pleural effusions, chronic obstructive pul monary disease, infiltrative cardiomyopathies, and anasarca. Hyperkalemia Mild-Moderate V1 V2 Moderate-Severe T V1 V2 P T P FIGURE 235-14 The earliest ECG change with hyperkalemia is usually peaking (“tenting”) of the T waves. With further increases in the serum potassium concentration, the QRS complexes widen, the P waves decrease in amplitude and may disappear, and nally a sine-wave pattern leads to asystole unless emergency therapy is given. (After AL Goldberger et al: Goldberger’s Clinical Electrocardiography: A Simplified Approach, 9th ed. Philadelphia, Elsevier/Saunders, 2017.) CHAPTER 235 Electrocardiography Very Severe Lead I Lead II 1mV 1s 1682 Hypokalemia Hypothermia II PART 6 Disorders of the Cardiovascular System I V3 Tricyclic overdose V2 V5 U Amiodarone V4 T Subarachnoid hemorrhage III V3 FIGURE 235-15 A variety of metabolic derangements, drug effects, and other factors may prolong ventricular repolarization with QT prolongation or prominent U waves. Prominent repolarization prolongation, particularly if due to hypokalemia, inherited “channelopathies,” or certain pharmacologic agents, indicates increased susceptibility to torsades des pointes ventricular tachycardia (Chap. 249). Marked systemic hypothermia is associated with a distinctive convex “hump” at the J point (Osborn wave, arrow) due to altered ventricular action potential characteristics. Note QRS and QT prolongation along with sinus tachycardia in the case of tricyclic antidepressant overdose. Hypocalcemia I II Normal I Hypercalcemia I II II QT 0.36 s QTc 0.41 QT 0.26 s QTc 0.36 QT 0.48 s QTc 0.52 FIGURE 235-16 Prolongation of the Q-T interval (ST-segment portion) is typical of hypocalcemia. Hypercalcemia may cause abbreviation of the ST segment and shortening of the QT interval. FIGURE 235-17 Classic triad of findings for pericardial effusion with cardiac tamponade: (1) sinus tachycardia; (2) low QRS voltages; and (3) electrical alternans (best seen in leads V3 and V4 in this case; arrows). This triad is highly speci c for pericardial effusion, usually with tamponade physiology, but of limited sensitivity. (Adapted from LA Nathanson et al: ECG Wave-Maven. http://ecg.bidmc.harvard.edu.) CHAPTER 236 Noninvasive Cardiac Imaging: Echocardiography, Nuclear Cardiology, and Magnetic Resonance/Computed Tomography Imaging 1683 ■ELECTRICAL ALTERNANS Electrical alternans—a beat-to-beat alternation in one or more compo nents of the ECG signal—is a common type of nonlinear cardiovascular response to a variety of hemodynamic and electrophysiologic pertur bations. Total electrical alternans (P-QRS-T) with sinus tachycardia is a relatively specific sign of pericardial effusion, usually with cardiac tamponade (Fig. 235-17). In contrast, pure repolarization (ST-T or U wave) alternans is a sign of electrical instability and may precede ventricular tachyarrhythmias. ■CLINICAL INTEPRERATION OF THE ECG Accurate analysis of ECGs requires thoroughness and care. The patient’s age, gender, and clinical status should always be taken into account. Many mistakes in ECG interpretation are errors of omission. Therefore, a systematic approach is essential. The following 14 points should be analyzed carefully in every ECG: (1) standardization (cali bration) and technical features (including lead placement and artifacts), (2) rhythm, (3) heart rate, (4) PR interval/AV conduction, (5) QRS interval, (6) QT/QTc intervals, (7) mean QRS electrical axis, (8) P waves, (9) QRS voltages, (10) precordial R-wave progression, (11) abnormal Q waves, (12) ST segments, (13) T waves, and (14) U waves. Compari son with any previous ECGs is invaluable. ■COMPUTERIZED ELECTROCARDIOGRAPHY Computerized systems are widely used for immediate retrieval of thousands of ECG records. Computer analysis of ECGs still has major limitations and, therefore, should not be accepted without careful cli nician review

POSTEST


Navigasi Sesi 2 dari 2 · Blok Kardiovaskular

Alur Sesi: 01 Pretest → 02 MATERI (AKTIF) → 03 POSTTEST

Broty: "Materi selesai dibaca. Lanjutkan ke posttest untuk mengevaluasi pemahamanmu pada sesi ini."

Built with LogoFlowershow